Trakka Sterilizing Record
and Tracking System (MK-4)
The Trakka Sterilizer Record and Tracking System is designed to
meet the record keeping requirements and "Patient to Process"
traceability of devices and instruments, in the modern Office Based
Practice.
The operator is able to implement an accurate Record and Tracking
System by documenting the sterilizer cycles as a check list, on
the Sterilizer Record Sheet. The System has several sections for
recording permanent Records.
Trakka
Sterilizer Record and Tracking System
1. An "Introduction and Instructions for using the Trakka
System"
2. Sterilizer Record Section per cycle.
100 x Sterilizer Sheets each page will facilitate six (6) Cycles.
Each cycle space will facilitate a Trakka Process Label and the
actual Sterilizer Streamer or "Print Out" by attaching
to the rear of the page. This keeps all records in the one place.
3. Daily Test Record Section.
This is a reminder to those with a Pre-Vacuum (Prevac) Bench top
Sterilizer to perform a warm up cycle with an empty chamber and
then record the "Leak Rate Test" and the "Bowie-Dick
Simulator Test". A place for attaching the adhesive "Bowie-Dick"
(Helix)
indicator or a Lot control/Hollow Instrument (Helix) - As per EN867-5
is provided.
4. Validation Records Section.
This section requires that all validation tests are performed in
accordance with the requirements of the Australia & New Zealand
Standard - AS/NZS 4815-2001.
5. Maintenance Record Section.
Please record all services, any malfunction and repairs carried
out.
6. Register of Authorized Operators.
The Practice Manager will appoint responsible operators that are
trained in cleaning, packing, sterilizing, recording and tracking.
Only these operators are permitted to "release" the processed
items to be used as "Sterile" or "Sterilized".
Each system requires a Trakka Sterilizing Record Book along with
5 X Rolls of the Trakka "Piggy Back" Process Indicator
Labels and 1 X Sharpie Industrial Marker Pen. (Always use a non
toxic marker pen on process labels or packs that are to be sterilized).
The pen is included.
The larger practice may require the Trakka Label Applicator. The
applicator is easy to use and certainly speeds up the labeling process.
The Trakka Sterilizing System is available via Majac Medical Products
or your preferred Supplier.
The New Trakka MK4 Label Applicator - Directions
For Loading Labels

order information:
| CODE |
DESCRIPTION |
| MK-4/L48-5 |
Trakka MK4 labels for MK4 Applicator - 5 rolls per pack
(2,500) |
| MK-4/L48-2 |
Trakka MK4 labels for MK4 Applicator - 2 rolls per pack (1,000) |
| T1002 |
Record Book - each book will record 600 cycles and includes
a Sharpie Industrial Marker |
| PB3-208 |
Trakka MK4 Label Applicator |
| S13801 |
Sharpie - Industrial Extra Fine 0.4 mm black permanent marker
|

|